توضیحات
High performing flowmeter with intelligent and dynamic adaptation to changing process conditions
The t-mass 65I was designed for the direct mass flow measurement of industrial gases and compressed air. With a turndown of typically 100:1 it can measure accurately operational flow rates and off line leakage. The integrated gas engine allows the customer to configure the device for 20 freely selectable gases. The t-mass 65I insertion version is suitable for large pipelines or rectangular ventilation ducts.
Benefits
- Measurement of gases and gas mixtures in circular piping or rectangular ducts
- Highest performance – high accuracy and repeatability for a wide range of utility and process gases
- Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free
- Reliable flow trending – multivariable measurement
- Fast and efficient commissioning – guided operating menus
- High plant availability – self-diagnostics and error monitoring
- Automatic recovery of data for servicing
Field of application
- Measuring principle is characterized by a high operable flow range and direct mass flow measurement
- Measurement of gases and gas mixtures in circular piping or rectangular ducts.
Device properties
- Insertion version for nominal diameter DN 80 to 1500 (3 to 60″)
- Medium temperature up to +130 °C (266 °F)
- High accuracy: ±1.5 % o.r. (10 to 100 % o.f.s.)
- Device in compact or remote version
- 4-20 mA HART, PROFIBUS PA/DP, Modbus RS485, FF
- Worldwide approvals (Hazardous area)
| Measuring Principle | Thermal | |
| Product headline | Mass flowmeter for measurement of standard single / mixture gas applications; insertion style | |
| Sensor features | S-DAT, T-DAT Quick Set-Up Dynamic temperature compensation 20 selectable gases Programmable gas mixture External pressure input 2 Totalizers For circular pipe or rectangular duct |
|
| Nominal diameter range | DN 80…1500 3″…60″ |
|
| Max. measured error | Mass: +-1.5% | |
| Measuring range | Gas and process condition dependent | |
| Max. process pressure | -0.5… 20 barg -7.25… 290 psig |
|
| Medium temperature range | -40… +130°C -40… +266°F |
|
| Degree of protection | IP 67 NEMA 4x |
|
| Display/Operation | Two line backlit LCD, alphanumeric (16 characters) Push buttons |
|
| Outputs | 2 x 0/4…20mA Pulse/Frequency (1KHz, active/passive) 2 x Relays Status |
|
| Inputs | Status 0/4…20mA |
|
| Digital communication | HART PROFIBUS DP MODBUS RS485 |
|
| Hazardous area approvals | ATEX FM CSA IEC Ex NEPSI |
|