Endress+Hauser Radar measurement Micropilot NMR81

Endress+Hauser Radar measurement Micropilot NMR81

Drip-off lens antenna with 79 GHz transmitting frequency for custody transfer applications

Micropilot NMR81 is used for custody transfer and inventory control applications with NMi- and PTB-approvals and meets the requirements according to OIML R85 and API 3.1B. NMR81 is particularly suited for free space applications up to 70m. The drip-off lens antenna with 79 GHz transmitting frequency produces a sharply focused beam angle of 3° and avoids obstacles even close to tank wall.

Benefits

  • Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy) for high level of safety
  • Maximum reliability through accuracy up to ±0.5mm (±0.02″)
  • Developed according to international metrology recommendations such as OIML R85 and API MPMS
  • Local and country-specific certifications like NMi or PTB for custody transfer applications
  • Simplified installation and trouble-free operations due to easy connection to major DCS systems via open protocols
  • 79GHz technology for narrow beam angle for sharper focus, without interference from tank wall and obstructions

Field of application

79 GHz drip-off lens antenna suited for free space applications up to 70m offers high beam focusing for applications with nozzle situated close to tank wall.

  • Process connections: Flanges
  • Temperature: -40 to +200°C (-40 to +392°F)
  • Pressure: Vacuum to +16bar (Vacuum to +232psi)
  • Maximum measuring range: 70m (230ft)
  • Accuracy: ±0.5mm (±0.02″)
  • Transmitting frequency: 79GHz
  • International explosion protection and custody transfer certificates, overfill prevention WHG, SIL
Measuring Principle Level radar
Characteristic / Application Lens antenna, 79GHz: High precision measurement for for storage tanks up to 30 m (98ft)
Specialities Custody transfer level measurement
Measurement close to tank wall
Supply / Communication 85-264VAC
Accuracy up to 0.5 mm
Ambient temperature Standard:
-40°C…60°C
(-40°F…140°F)
For calibration to regulatory standards:
-25°C…55°C
(-13°F…131°F)
Process temperature -40°C…200°C
(-40°F…392°F)
Process pressure absolute / max. overpressure limit Vacuum…..16 bar abs
Main wetted parts 316L, PTFE
Process connection Flange:
DN50/2″…DN300/12″
Flange w/ Alignment tool:
DN100/4″…DN300/12″
UNI-Flange
DN150/6″…DN300/12″
UNI-Flange w/ Alignment tool:
DN150/6″…DN300/12″
Max. measurement distance 70 m (230 ft)
For calibration to regulatory standards:
30 m (98 ft)
Communication Outputs:
Fieldbus: Modbus RS485, V1, HART
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)

Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/active)

Certificates / Approvals IEC Ex, ATEX, FM,
Safety approvals SIL
Metrological approvals and certificates OIML, NMi, PTB
Options Redundant fieldbus
Alu-coated or 316L housing
Weather protection cover
Adjustable mounting seals
Application limits Maximum measuring range is dependent on the tank form and/ or application